FESSH prep Hand infections Bone and joint

Kirschner-wire fixation in the hand and wrist: pin-site infection and other complications

Last reviewed v1

FESSH-152Hand infections●○○ basic

Regarding Kirschner-wire fixation in the hand and wrist and its complications:

  1. 1.Most pin-site infections after Kirschner-wire fixation in the hand and wrist are superficial and settle with local care, oral antibiotics or early wire removal.

  2. 2.Burying wires beneath the skin lowers the risk of pin-site infection compared with leaving them exposed, at the cost of a longer operation.

  3. 3.Empirical postoperative antibiotics have been shown to prevent pin-site infection after Kirschner-wire fixation in the hand and wrist.

  4. 4.Apart from infection, recognised complications of Kirschner-wire fixation in the hand and wrist include wire loosening or migration, loss of reduction, and tendon or nerve injury.

  5. 5.Because the superficial structures over the distal radius are mobile, blind percutaneous wiring there does not put the extensor tendons or the cephalic vein at risk.

FESSH marking: +1 per correct statement, 0 for blank, −1 for incorrect. Click the same TRUE/FALSE button twice to clear it.

Question ID
FESSH-152
First published
Last reviewed
Version
v1
Answer key and explanations — open after answering
  1. 1. Most pin-site infections after Kirschner-wire fixation in the hand and wrist are superficial and settle with local care, oral antibiotics or early wire removal.

    True

    In a cohort of 189 patients with 408 smooth wires, most complications were minor, chiefly superficial pin-track infection (6% of pins); major complications such as deep infection needing further surgery affected 3% of pins. In a review of 1,213 patients, 7% needed oral antibiotics, early pin removal or reoperation for a pin-site infection, and most infections were benign. Deep infection does occur: a systematic review of distal radius surgery describes escalation from oral antibiotics and local care to intravenous antibiotics, debridement and hardware removal for severe cases.

    • Hsu LP, Schwartz EG, Kalainov DM, Chen F, Makowiec RL. Complications of K-wire fixation in procedures involving the hand and wrist. J Hand Surg Am. 2011;36(4):610-6. PMID 21463725
    • van Leeuwen WF, van Hoorn BT, Chen N, Ring D. Kirschner wire pin site infection in hand and wrist fractures: incidence rate and risk factors. J Hand Surg Eur Vol. 2016;41(9):990-994. PMID 27464583
    • Cruciani A, Giuli C, Di Pietro G, Cianni L, Fulchignoni C, Del Vecchio P, et al.. Epidemiology and treatment of surgical infections after distal radius fractures: a systematic review. Arch Orthop Trauma Surg. 2025;145(1):483. PMID 41128924
  2. 2. Burying wires beneath the skin lowers the risk of pin-site infection compared with leaving them exposed, at the cost of a longer operation.

    True

    A 2024 meta-analysis of 11 studies of hand and forearm fractures found a lower risk of pin-site infection with buried wires (risk ratio 0.49), a longer operation and wires left in longer before removal, with no difference in the rate of early removal. Not every cohort shows the difference: in a series of 408 hand and wrist wires, pin exposure was not significantly related to complications.

    • Hidajat NN, Magetsari RMSN, Prasetiyo GT, Respati DRP, Tjandra KC. Buried or exposed Kirschner wire for the management of hand and forearm fractures: A systematic review, meta-analysis, and meta-regression. PLoS One. 2024;19(5):e0296149. PMID 38748687
    • Hsu LP, Schwartz EG, Kalainov DM, Chen F, Makowiec RL. Complications of K-wire fixation in procedures involving the hand and wrist. J Hand Surg Am. 2011;36(4):610-6. PMID 21463725
  3. 3. Empirical postoperative antibiotics have been shown to prevent pin-site infection after Kirschner-wire fixation in the hand and wrist.

    False

    In a cohort of 189 patients, empirical antibiotic treatment had no significant relationship with infectious complications; infection was associated with pin location in the hand rather than the wrist and with poor compliance with pin-site care. A review of 1,213 patients found no factor independently associated with pin-site infection. Prevention rests on careful wire placement and pin-site care, with prompt treatment when infection appears.

    • Hsu LP, Schwartz EG, Kalainov DM, Chen F, Makowiec RL. Complications of K-wire fixation in procedures involving the hand and wrist. J Hand Surg Am. 2011;36(4):610-6. PMID 21463725
    • van Leeuwen WF, van Hoorn BT, Chen N, Ring D. Kirschner wire pin site infection in hand and wrist fractures: incidence rate and risk factors. J Hand Surg Eur Vol. 2016;41(9):990-994. PMID 27464583
  4. 4. Apart from infection, recognised complications of Kirschner-wire fixation in the hand and wrist include wire loosening or migration, loss of reduction, and tendon or nerve injury.

    True

    In a review of 137 patients with 422 smooth pins, the overall complication rate was 18%: infection in 7% (osteomyelitis in two patients), loosening without infection in 4%, loss of reduction in 4%, symptomatic non-union in 4%, flexor tendon impalement, pin migration, and median nerve and radial artery injury. A second series of 590 wire fixations reported complications in 15.2% of patients, including osteomyelitis, tendon rupture, nerve lesion, pin-tract infection, loosening and migration, mostly from technical failure or poor patient compliance.

    • Botte MJ, Davis JL, Rose BA, von Schroeder HP, Gellman H, Zinberg EM, et al.. Complications of smooth pin fixation of fractures and dislocations in the hand and wrist. Clin Orthop Relat Res. 1992;(276):194-201. PMID 1537152
    • Stahl S, Schwartz O. Complications of K-wire fixation of fractures and dislocations in the hand and wrist. Arch Orthop Trauma Surg. 2001;121(9):527-30. PMID 11599756
  5. 5. Because the superficial structures over the distal radius are mobile, blind percutaneous wiring there does not put the extensor tendons or the cephalic vein at risk.

    False

    In a cadaver study simulating percutaneous fixation of a distal radius fracture, wires pierced the cephalic vein 4 times and extensor tendons 3 times (out of 18 in each case); superficial nerves were not hit but lay close to standard wire sites. The authors advised a mini-open approach and guiding devices. Injury to the superficial branch of the radial nerve is also reported after percutaneous pinning in clinical series.

    • Santoshi JA, Chaware PN, Pakhare AP, Rathinam BA. An Anatomical Study to Demonstrate the Proximity of Kirschner Wires to Structures at Risk in Percutaneous Pinning of Distal Radius Fractures. J Hand Microsurg. 2015;7(1):73-8. PMID 26078507