FESSH prep Anatomy Nerves and vessels

Cutaneous nerves at risk in hand and wrist incisions

Last reviewed v1

FESSH-117Anatomy●○○ basic

Regarding cutaneous nerves at risk during surgery at the hand and wrist:

  1. 1.The palmar cutaneous branch of the median nerve usually arises within the carpal tunnel.

  2. 2.In open carpal tunnel release, the incision is placed on the ring-finger axis to protect the palmar cutaneous branch of the median nerve.

  3. 3.Near the ulnar head the dorsal branch of the ulnar nerve usually runs as a single trunk.

  4. 4.The 6U and 6R wrist arthroscopy portals place the dorsal branch of the ulnar nerve at risk.

  5. 5.Kirschner wires inserted percutaneously through the radial styloid lie in a safe zone for the superficial radial nerve.

FESSH marking: +1 per correct statement, 0 for blank, −1 for incorrect. Click the same TRUE/FALSE button twice to clear it.

Question ID
FESSH-117
First published
Last reviewed
Version
v1
Answer key and explanations — open after answering
  1. 1. The palmar cutaneous branch of the median nerve usually arises within the carpal tunnel.

    False

    In Chaynes and colleagues' dissection of 35 hands, the branch arose from the radial side of the median nerve in the forearm, on average 44.3 mm proximal to the bistyloid line, and perforated the antebrachial fascia about 5.7 mm from that line before dividing in the palm. DaSilva and colleagues found its fine terminal fibres in the superficial loose connective tissue over the transverse carpal ligament, but none in the deep, dense part of the ligament.

    • Chaynes P, Bécue J, Vaysse P, Laude M. Relationships of the palmar cutaneous branch of the median nerve: a morphometric study. Surg Radiol Anat. 2004;26(4):275-80. PMID 14872288
    • DaSilva MF, Moore DC, Weiss AP, Akelman E, Sikirica M. Anatomy of the palmar cutaneous branch of the median nerve: clinical significance. J Hand Surg Am. 1996;21(4):639-43. PMID 8842958
  2. 2. In open carpal tunnel release, the incision is placed on the ring-finger axis to protect the palmar cutaneous branch of the median nerve.

    True

    DaSilva and colleagues recommend this placement; even so, the very small terminal fibres in the loose tissue over the transverse carpal ligament are divided in an open release. Hobbs and colleagues found no branch ulnar to the axial line of the ring finger in 25 fresh cadavers, and Chaynes and colleagues warn that an incision in line with the middle finger can injure the branch.

    • DaSilva MF, Moore DC, Weiss AP, Akelman E, Sikirica M. Anatomy of the palmar cutaneous branch of the median nerve: clinical significance. J Hand Surg Am. 1996;21(4):639-43. PMID 8842958
    • Hobbs RA, Magnussen PA, Tonkin MA. Palmar cutaneous branch of the median nerve. J Hand Surg Am. 1990;15(1):38-43. PMID 2299166
    • Chaynes P, Bécue J, Vaysse P, Laude M. Relationships of the palmar cutaneous branch of the median nerve: a morphometric study. Surg Radiol Anat. 2004;26(4):275-80. PMID 14872288
  3. 3. Near the ulnar head the dorsal branch of the ulnar nerve usually runs as a single trunk.

    False

    In Root and colleagues' dissection of 28 cadavers, an average of two branches (range one to four) were present at the level of the distal ulnar articular surface, at least one longitudinal branch crossed dorsal to the extensor carpi ulnaris tendon in 82%, and a transverse branch to the distal radioulnar joint was present in 71%. Identifying and protecting a single branch is therefore unlikely to make dorsal and ulnar exposures safe.

    • Root CG, London DA, Schroeder NS, Calfee RP. Anatomical relationships and branching patterns of the dorsal cutaneous branch of the ulnar nerve. J Hand Surg Am. 2013;38(6):1131-6. PMID 23707013
  4. 4. The 6U and 6R wrist arthroscopy portals place the dorsal branch of the ulnar nerve at risk.

    True

    Root and colleagues mapped the dorsal branch of the ulnar nerve on the ulnar side of the wrist in 28 cadavers and warn that the 6U, 6R and ulnar midcarpal arthroscopy portals may place it at risk. Atzei and colleagues likewise describe a risk of injuring the nerve with ulnar portals such as the 6U and direct foveal portals; in their anatomical study the risk in the sectors containing these portals was low with the forearm in supination or neutral rotation and moderate in pronation, so neutral rotation or supination is preferred when these portals are used.

    • Root CG, London DA, Schroeder NS, Calfee RP. Anatomical relationships and branching patterns of the dorsal cutaneous branch of the ulnar nerve. J Hand Surg Am. 2013;38(6):1131-6. PMID 23707013
    • Atzei A, Senesi L, Gesuita R, Chung SR, Luchetti R. Minimizing risk to the dorsal sensory branch of the ulnar nerve in wrist arthroscopy: an anatomical study. J Hand Surg Eur Vol. 2025;50(10):1309-1316. PMID 40019124
  5. 5. Kirschner wires inserted percutaneously through the radial styloid lie in a safe zone for the superficial radial nerve.

    False

    Ali and colleagues found that the branches of the superficial radial nerve pass close to the radial styloid, so pinning through the styloid is unsafe; the ulnar half of a triangle formed by the radial styloid, Lister's tubercle and the nerve's exit point was free of the nerve. In Singh and colleagues' series, a fifth of patients (8 of 40) had injury to the nerve after radial styloid wiring.

    • Ali AM, El-Alfy B, Attia H. Is there a safe zone to avoid superficial radial nerve injury with Kirschner wire fixation in the treatment of distal radius? A cadaveric study. J Clin Orthop Trauma. 2014;5(4):240-4. PMID 25983505
    • Singh S, Trikha P, Twyman R. Superficial radial nerve damage due to Kirschner wiring of the radius. Injury. 2005;36(2):330-2. PMID 15664599