FESSH prep Degenerative arthritis Finger joints
PIP joint arthritis: arthrodesis versus implant arthroplasty
Regarding arthrodesis and implant arthroplasty for arthritis of the proximal interphalangeal (PIP) joint:
1.For osteoarthritis of the index-finger PIP joint, comparative data show a lower complication risk after implant arthroplasty than after arthrodesis.
2.A volar approach for PIP joint silicone arthroplasty leaves the extensor mechanism intact.
3.Adequate bone stock and functioning tendons are prerequisites for PIP joint implant arthroplasty.
4.Pooled evidence shows a lower non-union rate after wire fixation than after screw fixation for proximal interphalangeal joint arthrodesis.
5.Pyrocarbon PIP joint implants have lower revision rates than silicone implants.
FESSH marking: +1 per correct statement, 0 for blank, −1 for incorrect. Click the same TRUE/FALSE button twice to clear it.
Answer key and explanations — open after answering
-
1. For osteoarthritis of the index-finger PIP joint, comparative data show a lower complication risk after implant arthroplasty than after arthrodesis.
False
In Vitale and colleagues' comparison of 65 arthroplasties and 14 arthrodeses of the index-finger PIP joint for osteoarthritis or post-traumatic arthritis, pain relief, satisfaction and Michigan Hand Questionnaire scores did not differ and arthroplasty preserved the preoperative arc, but the risk of complication was 4.3 times higher after arthroplasty. Whether arthroplasty suits the index finger is debated because of the coronal loads of pinch: Herren's review considers arthroplasty to give the best functional outcome even in the index finger, and Richards and colleagues report good medium-term results with silicone implants there, especially in lower-demand patients. The choice is made on the patient's goals, accepting a higher complication risk in exchange for motion.
- Vitale MA, Fruth KM, Rizzo M, Moran SL, Kakar S. Prosthetic Arthroplasty Versus Arthrodesis for Osteoarthritis and Posttraumatic Arthritis of the Index Finger Proximal Interphalangeal Joint. J Hand Surg Am. 2015;40(10):1937-48. PMID 26188383
- Herren D. The proximal interphalangeal joint: arthritis and deformity. EFORT Open Rev. 2019;4(6):254-262. PMID 31312517
- Richards T, Ingham L, Russell I, Newington D. The Long-term Results of Proximal Interphalangeal Joint Arthroplasty of the Osteoarthritic Index Finger. Hand (N Y). 2022;17(2):266-270. PMID 32452216
-
2. A volar approach for PIP joint silicone arthroplasty leaves the extensor mechanism intact.
True
Through the volar approach the joint is exposed without dividing the central slip or extensor mechanism, which Proubasta and colleagues considered an advantage of the technique; in their series every patient regained full active extension. Yamamoto and colleagues' systematic review found the largest postoperative arc, the least extension lag (about 5° against 14°) and the lowest revision rate (6% against 18%) with volar silicone arthroplasty compared with dorsally inserted surface replacement. Herren notes that the dorsal approach is nevertheless the most popular in Europe.
- Proubasta IR, Lamas CG, Natera L, Millan A. Silicone proximal interphalangeal joint arthroplasty for primary osteoarthritis using a volar approach. J Hand Surg Am. 2014;39(6):1075-81. PMID 24799141
- Yamamoto M, Malay S, Fujihara Y, Zhong L, Chung KC. A Systematic Review of Different Implants and Approaches for Proximal Interphalangeal Joint Arthroplasty. Plast Reconstr Surg. 2017;139(5):1139e-1151e. PMID 28445369
- Herren DB. Current European Practice in the Treatment of Proximal Interphalangeal Joint Arthritis. Hand Clin. 2017;33(3):489-500. PMID 28673625
-
3. Adequate bone stock and functioning tendons are prerequisites for PIP joint implant arthroplasty.
True
Herren's review lists adequate bone stock and functional tendons as requirements for a successful PIP joint replacement. Yamamoto and Chung likewise indicate fusion for painful finger joints with or without poor soft-tissue condition and reserve implant arthroplasty mainly for older patients, because implants may need later revision. Silicone implants also give limited lateral stability and correct pre-existing deformity poorly (Herren, 2017), a consideration when the joint is unstable or deformed.
- Herren D. The proximal interphalangeal joint: arthritis and deformity. EFORT Open Rev. 2019;4(6):254-262. PMID 31312517
- Yamamoto M, Chung KC. Joint Fusion and Arthroplasty in the Hand. Clin Plast Surg. 2019;46(3):479-488. PMID 31103091
- Herren DB. Current European Practice in the Treatment of Proximal Interphalangeal Joint Arthritis. Hand Clin. 2017;33(3):489-500. PMID 28673625
-
4. Pooled evidence shows a lower non-union rate after wire fixation than after screw fixation for proximal interphalangeal joint arthrodesis.
False
The review found the opposite direction, with lower non-union after screw fixation than after pooled wire techniques. The wire category included Kirschner-wire and tension-band constructs, so its pooled result is not a K-wire-only estimate. The review's abstract and full text report different numerical rates. The evidence is heterogeneous and mainly non-randomised, so it does not establish that one fixation method is best for every patient.
- Faulkner H, An V, Lawson RD, Graham DJ, Sivakumar BS. Proximal Interphalangeal Joint Arthrodesis Techniques: A Systematic Review. Hand (N Y). 2023;18(1):74-79. PMID 33682483
-
5. Pyrocarbon PIP joint implants have lower revision rates than silicone implants.
False
Chan and colleagues' systematic review found similar pain relief, arc of motion and strength with the two implants, but higher rates of revision and salvage after pyrocarbon arthroplasty, on low-level evidence. In Wagner and colleagues' series of 170 pyrocarbon arthroplasties, survival free of revision was 79% at 5 years, most revisions were for dislocation or for pain and stiffness, and revision risk was higher in post-traumatic arthritis; radiographic loosening or progressive instability was common but not associated with worse pain or motion. Herren regards silicone implants as the gold standard of implant choice.
- Chan K, Ayeni O, McKnight L, Ignacy TA, Farrokhyar F, Thoma A. Pyrocarbon versus silicone proximal interphalangeal joint arthroplasty: a systematic review. Plast Reconstr Surg. 2013;131(1):114-124. PMID 23271522
- Wagner ER, Weston JT, Houdek MT, Luo TD, Moran SL, Rizzo M. Medium-Term Outcomes With Pyrocarbon Proximal Interphalangeal Arthroplasty: A Study of 170 Consecutive Arthroplasties. J Hand Surg Am. 2018;43(9):797-805. PMID 30172276
- Herren D. The proximal interphalangeal joint: arthritis and deformity. EFORT Open Rev. 2019;4(6):254-262. PMID 31312517