FESSH prep Anatomy Bones and joints
Capsuloligamentous anatomy of the proximal interphalangeal joint
Regarding the capsuloligamentous anatomy of the proximal interphalangeal (PIP) joint:
1.The volar plate, rather than the collateral ligaments, is the primary restraint to radial and ulnar angulation of the PIP joint.
2.The volar plate has a fibrous distal portion attached to the base of the middle phalanx and a membranous proximal portion continuous with the check-rein ligaments.
3.Histologically, the central core of the volar plate contains collagen fibres woven in two perpendicular planes, which may help it resist longitudinal and torsional stress.
4.The volar plate plays little part in preventing hyperextension of the PIP joint.
5.The accessory collateral ligament lies between the proper collateral ligament and the volar plate and is less substantial than the proper collateral ligament.
FESSH marking: +1 per correct statement, 0 for blank, −1 for incorrect. Click the same TRUE/FALSE button twice to clear it.
Answer key and explanations — open after answering
-
1. The volar plate, rather than the collateral ligaments, is the primary restraint to radial and ulnar angulation of the PIP joint.
False
In Rhee and colleagues' loading study of 68 cadaver PIP joints, the collateral ligament was confirmed as the primary restraint against side-to-side stress, and other supporting structures, including the palmar (volar) plate, did not contribute significantly to side-to-side stability. Kiefhaber and colleagues, testing 112 joints, likewise found the proper (lateral) collateral ligament to be the primary restraint to varus and valgus angulation.
- Rhee RY, Reading G, Wray RC. A biomechanical study of the collateral ligaments of the proximal interphalangeal joint. J Hand Surg Am. 1992;17(1):157-63. PMID 1538100
- Kiefhaber TR, Stern PJ, Grood ES. Lateral stability of the proximal interphalangeal joint. J Hand Surg Am. 1986;11(5):661-9. PMID 3760491
-
2. The volar plate has a fibrous distal portion attached to the base of the middle phalanx and a membranous proximal portion continuous with the check-rein ligaments.
True
Lee and colleagues dissected 16 cadaveric specimens and reconstructed them in three dimensions. The palmar (volar) plate consisted of a distal fibrous portion and a proximal membranous portion; it anchored distally on the base of the middle phalanx and was continuous proximally with the paired check-rein ligaments. The accessory collateral ligaments and the A3 pulley suspended the plate laterally.
- Lee SW, Ng ZY, Fogg QA. Three-dimensional analysis of the palmar plate and collateral ligaments at the proximal interphalangeal joint. J Hand Surg Eur Vol. 2014;39(4):391-7. PMID 23739145
-
3. Histologically, the central core of the volar plate contains collagen fibres woven in two perpendicular planes, which may help it resist longitudinal and torsional stress.
True
Williams and colleagues examined cadaver volar plates microscopically and found a three-layered structure, with differently oriented collagen in the volar, central core and dorsal check-rein sections. The central core contained a dense 'basket weave' of collagen fibres in two perpendicular planes, which the authors suggest may contribute primarily to the plate's resistance to both longitudinal and torsional stress.
- Williams EH, McCarthy E, Bickel KD. The histologic anatomy of the volar plate. J Hand Surg Am. 1998;23(5):805-10. PMID 9763253
-
4. The volar plate plays little part in preventing hyperextension of the PIP joint.
False
The volar plate restrains hyperextension of the PIP joint, and Williams and colleagues describe it as critical to joint stability. In a cadaver model of hyperextension laxity, Wright and colleagues incised the proximal volar plate and loaded the joint to 30° of hyperextension, which significantly increased the extension angle; volar plate repair reduced it again. Micev and colleagues produced traumatic hyperextension instability by dividing the volar plate together with the accessory collateral ligaments.
- Wright D, Lee C, Shin SS, McGarry MH, Lee TQ. Biomechanical Comparison of Volar Plate Repair Versus Volar Plate Repair With Suture Tape Augmentation at the Finger Proximal Interphalangeal Joint. J Hand Surg Am. 2025;50(10):1273.e1-1273.e7. PMID 39665732
- Micev AJ, Saucedo JM, Kalainov DM, Wang L, Ma M, Yaffe MA. Surgical Techniques for Correction of Traumatic Hyperextension Instability of the Proximal Interphalangeal Joint: A Biomechanical Study. J Hand Surg Am. 2015;40(8):1631-7. PMID 26143967
- Williams EH, McCarthy E, Bickel KD. The histologic anatomy of the volar plate. J Hand Surg Am. 1998;23(5):805-10. PMID 9763253
-
5. The accessory collateral ligament lies between the proper collateral ligament and the volar plate and is less substantial than the proper collateral ligament.
True
In Allison's microdissection of 8 PIP joints, the proper collateral ligament arose widely from the side of the head of the proximal phalanx and inserted along most of the side of the base of the middle phalanx; it was stout, with fibres parallel to the middle phalanx in all joint positions. The accessory collateral ligament was a less substantial structure lying between the proper collateral ligament and the volar plate.
- Allison DM. Anatomy of the collateral ligaments of the proximal interphalangeal joint. J Hand Surg Am. 2005;30(5):1026-31. PMID 16182063